| 许晨阳,许峥,王梅云,李志洁,文泽军.基于不同重建参数光子计数CT预测胃癌T分期[J].中国介入影像与治疗学,2026,23(6):376-380 |
| 基于不同重建参数光子计数CT预测胃癌T分期 |
| Photon-counting CT based on different reconstruction parameters for predicting T-stage of gastric cancer |
| 投稿时间:2026-03-23 修订日期:2026-05-11 |
| DOI:10.13929/j.issn.1672-8475.2026.06.011 |
| 中文关键词: 胃肿瘤 光子 体层摄影术,X线计算机 卷积核 量子迭代重建 |
| 英文关键词:stomach neoplasms photons tomography,X-ray computed convolution kernel quantum iterative reconstruction |
| 基金项目: |
|
| 摘要点击次数: 0 |
| 全文下载次数: 0 |
| 中文摘要: |
| 目的 观察基于不同参数重建光子计数CT预测胃癌T分期的价值。方法 回顾性收集14例接受腹部增强光子计数CT扫描的胃癌患者,分别基于不同卷积核(BR40、BR48、BR56)+不同等级量子迭代重建(QIR)技术(Q2、Q3、Q4)组合方案进行重建,共获得9组CT图像;以病理学结果为金标准,对比观察上述图像用于胃癌T分期的效能。结果BR40及BR48重建图像中,基于Q2及Q3评估胃癌T分期的准确率均为85.71%(12/14)、Q4达100%(14/14);且基于BR40+Q4及BR48+Q4评估结果与金标准的一致性极高(κ均=1.000),而基于BR40+Q2、BR40+Q3、BR48+Q2及BR48+Q3评估结果与金标准的一致性均较高(κ均=0.763)。BR56重建图像中,基于Q2、Q3、Q4的评估准确率分别为57.14%(8/14)、35.71%(5/14)及42.86%(6/14),与金标准的一致性均差(κ=0.354、0.149、0.211)。9种重建图像之间,信噪比(SNR)和对比度噪声比(CNR)差异均有统计学意义(P均<0.001),均以BR40+Q4方案较佳。结论 基于BR40+Q4重建光子计数CT用于预测胃癌T分期效能较佳。 |
| 英文摘要: |
| Objective To observe the value of photon-counting CT based on different reconstruction parameters for predicting T-stage of gastric cancer. Methods Totally 14 patients with gastric cancer who underwent abdominal enhanced photon-counting CT scanning were retrospectively enrolled. CT images were reconstructed with different combinations of different convolution kernels,i.e. (BR40, BR48, BR56)+different quantum iterative reconstruction (QIR) techniques (Q2, Q3, Q4), and 9 sets of images were finally obtained. Taken pathological results as the gold standards, the efficacy of the above images for predicting T-staging of gastric cancer was observed and compared. Results Among BR40 and BR48 reconstructed images, the accuracy based on Q2 and Q3 for predicting T-stage of gastric cancer were both 85.71% (12/14), of Q4 were both 100% (14/14), and the consistency of BR40+Q4 and BR48+Q4 with gold standards were both extremely high (both κ=1.000), while of BR40+Q2, BR40+Q3, BR48+Q2, BR48+Q3 with the gold standards were all relatively high (all κ=0.763). Among BR56 reconstructed images, the accuracy based on Q2, Q3 and Q4 was 57.14% (8/14), 35.71% (5/14) and 42.86% (6/14), respectively, all had poor consistency with the gold standards (κ=0.354, 0.149, 0.211). Significant differences of signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were found among 9 sets of images (both P<0.001), and BR40+Q4 was the best. Conclusion Photon-counting reconstructed CT images based on BR40+Q4 had better efficacy for predicting T-stage of gastric cancer. |
| 查看全文 查看/发表评论 下载PDF阅读器 |
| 关闭 |